Giới thiệu Mô-đun rơ le thời gian 6-30v tự hoàn thành
"100% brand new and high quality Material: Electrical components Color: See pictures Product introduction: 1. Operating voltage: 6--30V 2. Trigger Signal Source: High Level Trigger (3.0 V-24 V), signal ground and system ground are not common, which can increase anti-interference abilit system (short circuit can also connect with a ground common) 3. Output Capacity: can control no more than DC 30V 5A AC or 220 V devices 5A 4. Optocoupler Isolation: improve the anti-interference ability, after the parameter setting, it will memory forever Warning: Relay contact is passive and electricity production; 1 channel has the control function on / off Operation mode: P1: After triggered signal, power relay on time OP, then turn off; within the OP period following operation: 1) P1.1: signal being triggered again is not effective 2) P1.2: signal being triggered again, start time again 3) P1.3: signal being triggered again, reset; disconnect relay, stop timing P2: giving the trigger signal, the time after shutdown relay CL power relay OP time; then timing, turn off the relay P3.1: give the trigger signal after the power relay on time OP, CL shutdown time relay; then operating cycle above cycle gaive signal again, shutdown relay stop timing; cycle times (LOP) can be set P3.2: after connecting. no need to trigger signal, power relay on time OP, CL shutdown time relay; then the operating cycle above timea cycle (LOP) can be set Q4: keeping the function of the signal; if there is no trigger signal, the time will be canceled, relay stay connected; when the signal disappears, timing OP turn off the relay; over time, if no signal again, the time is cleared Time interval: 0.1 s (minimum) ~ 999 min (maximum) continuously adjustable how to choose the time interval: in the selection of parameter set interface mode, and press the STOP button to select the time How to set the parameter:
Activate Relay mode: 1. NO: PO in power over time, relay can be connected 2. OFF: relay is not allowed to connect, when in the off state in short main interface press the STOP key to achieve turn ON and OFF, current state will flash; then back to the main interface (this function is a function of sudden stop, 1 key to turn off the relay) Sleep Mode: C-P Sleep mode: within 5 minutes, no operation; nixie tube will close auto display, and a function program well The d-Normal Mode: nixie tube show ever Note: Press and hold STOP button for 2 seconds can achieve change from C-P to O-d; Current state will flash and then return to the main interface Size: 6.3*3.8*1.5cm/2.48""*1.50""*0.59"" No retail package Quantity:1Pc
Note: Due to the difference between different monitors, the picture may not reflect the actual color of the item. Thank you!! "